WT-1010C2 USER MANUAL
WT-1010C2
USER MANUAL
Rev.3.9
Technical Support: Technical@witura.com
COPYRIGHT ©2011
WITURA CORPORATION SDN BHD
To turn on this function, you can press *30* to proceed.
Example: Setting the unit to generate an Alert Message, call the administrators, generate a pulse
(+V) and sound the audible alarm when PSTN failed.
Simply input 11111#
Description:
“ME” stands for generation of SMS when PSTN failed. Default: 0
“OU” stands for generation of pulse (+V) at PIN15 when PSTN failed. Default: 0
“AL” stands for sounding the audible alarm when PSTN failed. Default: 0
“CA1” stands for calling the administrators when PSTN failed. Default: 0
“CA2” stands for calling the administrators when PSTN connected. Default: 0
Value: ON (1) or OFF (0)
Note: Audible Alarm will not work when AC power is unavailable
Auxiliary PSTN Failure Output Facility via PIN15
In additional to the alarm and text alert on PSTN failure the system also has a permanent +V
output continuously supplied from the unit via PIN15 output which will remain available for the
period of PSTN unavailable.
PST: ME: OU: AL:
CA1: CA2:
PST: ME: 1 OU: 1 AL: 1
CA: 1 CA2: 1
PST: ME: 1 OU: 1 AL: 1
CA: 1 CA2: 1 OK
Step 10. Setting for PSTN Failure