WT-1011RC IP65 GSM Remote Controller
And Alarm S
y
stem
WT-1011RC IP65 – USER MANUAL – Rev.1.6 – Technical Support: [email protected]
COPYRIGHT ©2010
WITURA CORPORATION SDN BHD
Function 3:
Function as pulse counter
Activates the output relay 2 to stay ON
Sends a programmable input alert message (*STR2#) once input triggered
Audible alarm will sound if the alarms function is turned on (*ALM2#1)
Function 4:
Function as pulse counter
Activates the output relay 2 for 2 seconds
Sends a programmable input alert message (*STR2#) once input triggered
Audible alarm will sound if the alarms function is turned on (*ALM2#1)
Function 5:
Function as pulse counter
Activates the output relay 2 with function *PWT2# and *PWK2#
Sends a programmable input alert message (*STR2#) once input triggered
Audible alarm will sound if the alarms function is turned on (*ALM2#1)
* For more details on functions of *PWT[N]# and *PWK[N]# please refer to Miscellaneous
Settings on page
Function 6:
Function as pulse counter
Activates the output relay 2 with function *PWT2# and *PWK2#
Audible alarm will sound if the alarms function is turned on (*ALM2#1)
Function 7:
Function as pulse counter
Sends a programmable input alert message (*STR2#) once input triggered
Audible alarm will sound if the alarms function is turned on (*ALM2#1)
Function 8:
Function as pulse counter
Sends a programmable input alert message (*STR2#) once input triggered
Sends a programmable input alert message (*STO2#) once input returned to
normal
Audible alarm will sound if the alarms function is turned on (*ALM2#1)
Example:
Assume that you want to use input 1 for pulse counter only; you would send the
following SMS message to the unit.