Witura WT-9001 IP65 Uživatelský manuál Strana 27

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 31
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 26
27
WT-9001 IP65 GSM Remote Control And Alarm System
WT-9001 IP65 USER MANUAL Rev. 3.4 Technical Support: technical@witura.com
COPYRIGHT ©2008 WITURA CORPORATION SDN BHD
The unit is reset successfully.
The system has the function to activate the relay for a specific time and then be
deactivated for a specific time in a repeating process. To set the opening & closing time
of the relays, you can send the following SMS command to the unit. Note: This function
only applied in input function 5 and 6.
Text Command for Opening time:
*PWT[N]#XXXXX
N stands for Output number 1 8
XXXXX stands for 5 digits value: The number of seconds
Text Command for Closing time:
*PWK[N]#XXXXX
N stands for Output number 1 8
XXXXX stands for 5 digits value: The number of seconds
Example:
Opening time of output 1 is set as 1 minute (*PWT1#00060) and the Closing time as 5
seconds (*PWK1#00005) and function 5 is applied on Input 1. When input 1 triggered,
output relay 1 will be activated for 1 minute and close for 5 seconds and then back on
for 1 minute and close again for 5 seconds and will keep on repeating the process until
the command *RLY1#00000 or *RLNU#00000000 is issued.
5.6.14 Setting the Function of Opening & Closing time for Output Relay
5.6.15 Auto Restart System