WITURA CORPORATION SDN BHD
The system has the function to activate the relay for a specific time and then be
deactivated for a specific time in a repeating process. To set the opening & closing time
of the relays, you can send the following SMS command to the unit. Note: This function
only applied in input function 5 and 6.
Text Command for Opening time:
*PWT[N]#X
N stands for Output number 1 – 8
X stands for the number of seconds for relay to stay on. Range from 0 - 9999999
To query relay on time, you can send SMS command *PWT?#[N]
Text Command for Closing time:
*PWK[N]#X
N stands for Output number 1 – 8
X stands for the number of seconds for relay to stay off. Range from 0 - 9999999
To query relay off time, you can send SMS command *PWK?#[N]
Example:
Opening time of output 1 is set as 1 minute (*PWT1#60) and the Closing time as 5
seconds (*PWK1#5) and function 5 is applied on Input 1. When input 1 is triggered,
output relay 1 will be activated for 1 minute and close for 5 seconds and then back on
for 1 minute and close again for 5 seconds.
The system has the function to sound the connected audible siren when input triggered.
This output is available on the connection PIN50 and ground on the PIN49. To turn
On/Off this function, you can send the following SMS command to the unit.
Text Command:
*ALM[N]#X
5.5 ALARM SETTINGS
5.5.1 Turning the Audible Siren Functions On/Off When Inputs Triggered
5.4.13 Setting the Function of Opening & Closing time for Output Relay