WT-9001 IP65 GSM Remote Monitorin
g
& Remote Control S
y
stem
WT-9001 IP65 – USER MANUAL – Rev. 4.7 – Technical Support: [email protected]
COPYRIGHT ©2011
WITURA CORPORATION SDN BHD
N stands for Input number 112
X stands for ON (1) or OFF (0) value
When *ALM1#1 is applied, means audible alarm will sound when Input 1 triggered.
When *ALM1#0 (Default) is applied, means audible alarm will not sound when Input 1
triggered.
To check the audible siren function setting, you can send *ALM?#[N]
The alarm siren can be set to determine how long the siren will remain active and this
can be done by sending the following SMS command to the unit.
Text Command:
*ALTM#X
X stands for the number of seconds. Range from 0-9999999
Example:
When *ALTM#3600 is applied, means the audible alarm will sound for 1 hour when
triggered
To check the Alarm time setting, you can send *ALTM?#
The system has the function to send a text alert in the event the main power is lost and
the system is relying on battery back up.
It is also possible to activate and deactivate this function by sending the unit an SMS
Message.
Text Command:
*ALAC#X
X stands for ON (1) or OFF (0) value
When ever the *ALAC#1 command is activated and the power down alarm is on any of
the Administrators programmed to receive text alerts, will receive the following
messages from the unit in the event of power down and also when power is restored.
5.5.2 Setting the Alarm Time For Audible Alarm (Default: 600 seconds)
5.5.3 Power Down Alarm